It looks like you may be intermixing TRAJ I/O commands with MERGE commands.

Note also that SKIP values are in integration steps, not time units.

When reading trajectory files, the number and ordering of atoms must match exactly what is in the PSF. The MERGE command does allow the writing of a subset of atoms, but requires another trajectory as input data.


Rick Venable