Joined: Feb 2006
Posts: 23
Forum Member
|
OP
Forum Member
Joined: Feb 2006
Posts: 23 |
Hello, I am using coor orient rms to orient a section of my protein on top of the same section from another protein, and despite having coordinates in the comparison and main set for the atoms of interest, I am getting a warning: CHARMM> coor orient rms sele coil end SELRPN> 550 atoms have been selected out of 10825 **WARNING** ALL SELECTED COORDINATES UNDEFINED
**** WARNING **** FOR THIS OPERATION, THERE WERE 550 MISSING COORDINATES
and the protein does not align. I am pasting my input text below in hopes that someone might notice any sequence that may be problematic. Thank you.
! Read in topology parameter definitions and add zincpatch read rtf card name /data6/c/jasonwan/charmm/toppar/top_all22_prot.inp read param card name /data6/c/jasonwan/charmm/toppar/par_all22_prot.inp read rtf card APPEND name /data6/c/jasonwan/charmm/toppar/patchtest/toppar_all22_prot_zincpatch.inp
read univ * modified pdb setup * pdb w 61 6 end
open unit 21 read form name /data6/c/jasonwan/models/1ca9.c read sequence pdb unit 21 gener 1CA9 first NTER last CTER setup warn rewind unit 21 read coor univ unit 21 offset 0 close unit 21
open unit 22 read form name /data6/c/jasonwan/models/1cb9.c read sequence pdb unit 22 gener 1CB9 first NTER last CTER setup warn rewind unit 22 read coor univ unit 22 offset 191 close unit 22
open unit 23 read form name /data6/c/jasonwan/models/1cc9.c read sequence pdb unit 23 gener 1CC9 first NTER last CTER setup warn rewind unit 23 read coor univ unit 23 offset 382 close unit 23
ic param ! GET MISSING BONDS AND ANGLES FROM PARAMETER FILE ic purge ! CLEAN UP THE IC TABLE ic fill preserve ! RECOMPUTE IC VALUES FROM COORDS ic build ! PLACE ANY MISSING COORDS, E.G. TERMINAL O ON CO2- ic fill update
! Orient 1CA9 trimer w/ XYaxis coor orient mass sele ires 3 : 36 .and. segid 1CA9 .or. ires 3 : 36 .and. segid 1CB9 .or. ires 3 : 36 .and. segid 1CC9 end
! temp save to see how trimer centered write coor pdb name 1cabc9_x.crd.pdb * 1CABC9 three chains align x *
! remove the other two chains Delete atoms sele segid 1CB9 end Delete atoms sele segid 1CC9 end
! Save chain 1CA9 ! Write PSF and CRD write psf card name 1ca9_x.psf * 1CA9 chain A align x * write coor card name 1ca9_x.crd * 1CA9 chain A align x * write coor pdb name 1ca9_x.crd.pdb * 1CA9 chain A align x *
! Save coordinates also in comparsion coordinate set for later use !coor copy comp coor copy comp sele ires 3 : 36 .and. segid 1CA9 show end
! do you need to remove the 1CA9 chain here? !Delete atoms sele segid 1CA9 end
! read in model open unit 21 read form name /data6/c/jasonwan/models/model5b6a.chh read sequence pdb unit 21 gener 5b6A first NTER last CTER setup warn rewind unit 21 read coor univ unit 21 offset 191 close unit 21
! check to see if we have it all (except the hydrogens) print coor select .not. hydrogen .and. .not. initialized end
ic param ! GET MISSING BONDS AND ANGLES FROM PARAMETER FILE ic purge ! CLEAN UP THE IC TABLE ic fill preserve ! RECOMPUTE IC VALUES FROM COORDS ic build ! PLACE ANY MISSING COORDS, E.G. TERMINAL O ON CO2- hbuild sele segid 5b6A .and. type H* show end !(RE)CONSTRUCT H ATOMS; ROTATE -OH and -CH3 update
print coor
! Orient kinked coil w/ 1CA9 monomer define coil sele segid 5b6A .and. ires 504 : 537 show end coor orient rms sele coil end
|
|
|
|
Joined: Sep 2003
Posts: 8,650 Likes: 26
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 8,650 Likes: 26 |
Check for more informative messages earlier in your output.
Rick Venable computational chemist
|
|
|
|
Joined: Sep 2003
Posts: 4,881 Likes: 12
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 4,881 Likes: 12 |
I think you have generated one PSF containing pieces from two different proteins. It is not at all clear to me that you actually have coordinates that can be compared. CHARMM is not too happy about handling two different proteins at the same time; this would require quite a bit of tweaking (one PSF and two conformations is OK though). To simplify matters I would recommend that you create your PSF first and then write two CHARMM coordinate files (one for each structure). Finally run a separate job to compare the two. "divide and conquer" remains the basic rule of troubleshooting.
Lennart Nilsson Karolinska Institutet Stockholm, Sweden
|
|
|
|
Joined: Sep 2003
Posts: 8,650 Likes: 26
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 8,650 Likes: 26 |
It's possible to do what you're attempting, but not that way.
Since the COOR COPY COMP command was before you added a new segment, the later COOR ORIE RMS will fail because there are no coords for the new segment in the COMP set. After generating the new segment, you need to do something like
coor copy comp ! COPY ALL ATOMS coor dupl comp sele atoms-from-protein1 end sele atoms-from-protein2 end coor orient rms sele atoms-from-protein2 end
where atoms-from-protein1 etc. is some atom selection that identifies the matching regions. Note that the number of atoms and their correspondence in the two atom selections must be exact. If the amino acid sequences are not identical, you must explicitly account for that by the atom selections (e.g. limit to backbone).
Rick Venable computational chemist
|
|
|
|
Joined: Feb 2006
Posts: 23
Forum Member
|
OP
Forum Member
Joined: Feb 2006
Posts: 23 |
The coor dupl comp after generating all the segments did exactly what I wanted for the orientation. I had also started breaking up the input scripts for the divide and conquer method before finding the aforementioned worked. Thank you both!
By the way, what does the dupl do- does it let the comp set have two different coord sets?
Last edited by metalman; 02/24/06 03:44 PM.
|
|
|
|
Joined: Feb 2006
Posts: 23
Forum Member
|
OP
Forum Member
Joined: Feb 2006
Posts: 23 |
8) The DUPLicate command.
The DUPLicate command copies coordinates between atoms within a structure. The coordinates are copied FROM the first selection TO the second selection. If the selections overlap, watch out!. The matching is done by number within the selected coordinate sets. If the two selection have a different number of atoms, a warning will be issued, and the smaller number will be used. For example, if one needs to compute the relative orientation between two alpha helicies, the following input might be used;
COOR COPY COMP COOR DUPL COMP SELE backbone of first END SELE backbone of second END COOR ORIE RMS MASS COMP SELE backbone of second END
This will give the RMS shift between these helicies as well as the coordinate transformation required to map one into the other. The PREVious option may be used with a single atom selection. This assigns the coordinate position of selected atoms to the value of the previous atom (by number). This has been used with the command; COOR DUPLicate PREVious SELE TYPE H* END to assign hydrogen atom positions to that of the associated heavy atom. The COMP keyword causes only the comparison coordinates to be used and modified. Otherwise, the entire operation involves only the main coordinates.
|
|
|
|
|
|