Re: lipid C-D order parameters using CORREL
rmv #34480 10/07/14 03:49 PM
Joined: Sep 2003
Posts: 4,784
Likes: 2
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 4,784
Likes: 2
correl.doc provides the syntax for its traj subcommand; see also dynamc.doc.

We do not know how you specified only one frame, because you have not shown us the traj command you used. Does your trajectory contain more than one frame?


Lennart Nilsson
Karolinska Institutet
Stockholm, Sweden
Re: lipid C-D order parameters using CORREL
rmv #34481 10/07/14 06:20 PM
Joined: Sep 2003
Posts: 8,485
rmv Offline OP
Forum Member
OP Offline
Forum Member
Joined: Sep 2003
Posts: 8,485
I should note that the script computes averages for a given C-H vector over all lipids and time points, but does not average the two values for the two vectors on the same C atom; you would need to that. They are not averaged because the equivalence of the two values is an indication of convergence; for a well converged analysis interval, the values should agree fairly closely.


Rick Venable
computational chemist

Re: lipid C-D order parameters using CORREL
rmv #37959 07/05/20 07:14 PM
Joined: Aug 2009
Posts: 132
L
lqz Offline
Forum Member
Offline
Forum Member
L
Joined: Aug 2009
Posts: 132
Hi, can we use above code to calculate the order parameters of PIP2? It looks like it also has the specified carbon atoms.