I have some of the output file below:
CHARMM> ! put the complex in a water box
CHARMM> read sequ tip3 21173

CHARMM> gene wat1 noangle nodihe
NO PATCHING WILL BE DONE ON THE FIRST RESIDUE
NO PATCHING WILL BE DONE ON THE LAST RESIDUE
GENPSF> Segment 2 has been generated. Its identifier is WAT1.
PSFSUM> PSF modified: NONBOND lists and IMAGE atoms cleared.
PSFSUM> Summary of the structure file counters :
Number of segments = 2 Number of residues = 21745
Number of atoms = 72299 Number of groups = 23862
Number of bonds = 72427 Number of angles = 37194
Number of dihedrals = 23549 Number of impropers = 1535
Number of cross-terms = 570
Number of HB acceptors = 22035 Number of HB donors = 973
Number of NB exclusions = 0 Total charge = -17.00000
QXFORM> Expanded format used.
More than 4 character RESID used.

I wonder how to deal with it.Thanks!

Re: How to deal with expanded format??
accelrys #11593 08/23/06 08:56 AM
Joined: Sep 2003
Posts: 4,772
Likes: 2
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 4,772
Likes: 2
This is just an informative message, and no error condition. You don't have to deal with it; CHARMM deals with it for you.


Lennart Nilsson
Karolinska Institutet
Stockholm, Sweden
Re: How to deal with expanded format??
lennart #11594 08/24/06 12:45 AM
Joined: Jun 2006
Posts: 21
A
Forum Member
OP Offline
Forum Member
A
Joined: Jun 2006
Posts: 21
Thanks,professor. But my crd file which produced together with this output file has many errors read by VMD as following.
error> Base molecule :Excessive bonding errors encountered,perhaps atom coodinates are in the wrong units?
error> Base molecule :Silencing bonding error messeges.
<warning> Unusual bond between residues: 3 <protein> and 11251 <water>
.
.
.

I am sure that my initial model before putting into the water box is minimized without error.
I do not know what caused this.

Re: How to deal with expanded format??
accelrys #11595 08/24/06 01:44 AM
Joined: Sep 2003
Posts: 8,450
rmv Online Content
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 8,450
If CHARMM can re-read the file, then it may be a VMD error; only newer versions of VMD can read the CHARMM expanded format coord files, and a "plug-in" may be needed.


Rick Venable