how can i select a right timestep in MD (molecular dynamics)?
#10000 03/19/06 11:20 PM
Joined: Mar 2006
Posts: 18
P
Forum Member
OP Offline
Forum Member
P
Joined: Mar 2006
Posts: 18
i am wondering at this problem. i was told that, if the timestep is too small, then the simulation runs very slow,if it is too big, the the error will increase. so we should choose a right timestep with acceptable error and maximum speed. but what is the criteria? i have looked at some inp file of charmm, and found they mostly choose a timestep of 0.002 ps. but i do not know why?
thank you for your kind help.

Last edited by parachuter; 03/19/06 11:21 PM.
Re: how can i select a right timestep in MD (molecular dynamics)?
parachuter #10001 03/19/06 11:58 PM
Joined: Sep 2003
Posts: 8,576
Likes: 11
rmv Online Content
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 8,576
Likes: 11
In most cases, use of 0.002 ps is tolerable (but not ideal) if one constrains the bonds to hydrogens via e.g.

SHAKE BONH PARAM

This removes the high frequency C-H, N-H, and O-H vibrations (think of an IR spectrum), and provides some rationale for the larger 0.002 ps timestep. However, we've observed differences in calculated properties between simulations run at 0.001 and 0.002 ps, so we mainly use the smaller 0.001 ps value.


Rick Venable