What I want to do is calculating the solvated energy of DNA by gbmv approach. All I can find about this topic is the test script in charmm. I used the second analytical method. Is the parameter setting good enough to accomplish the task? Thanks a lot!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! faster on update cutnb 999 ctofnb 998 ctonnb 997 eps 1 vswi switch
!************************************ ! Set version # to PARAM19, parameters were fitted to PARAM22. ! However, errors are pretty small < 1.5 % for PARAM19. ! Errors are ~ 1 % for PARAM22 vs. 0.25 A - PB Calculations !************************************
set ver = 19 if ver .eq. 22 set GBPARAMS = SHIFT -0.102 SLOPE 0.9085 if ver .eq. 19 set GBPARAMS = SHIFT -0.102 SLOPE 0.9085
!*********************************************** ! Start GBMV, Method II: Recommended parameters ! Non-zero SA term turns on surface area. ! By default, no SA term is calculated. !***********************************************
GBMV BETA -20 EPSILON 80 DN 1.0 watr 1.4 GEOM - TOL 1e-8 BUFR 0.5 Mem 10 CUTA 20 HSX1 -0.125 HSX2 0.25 - ALFRQ 1 EMP 1.5 P4 0.0 P6 8.0 P3 0.70 ONX 1.9 OFFX 2.1 - SON 0.5 SOFF 1.75 - WTYP 2 NPHI 38 CORR 1 SA 0.00592 SB 0.0 @GBPARAMS
!************************************ ! Simple energy evaluation and alpha show !************************************ energy
scalar gbalpha show
!************************************ ! Minimization should go downhill !************************************
mini abnr nstep 1000
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Last edited by Zhiguo; 11/16/09 04:44 PM.
--------------------------- CHARMM c32b1 driven by RHEL 2.6.9-22.0.2 on PPC64
|
|
|
|
Joined: Sep 2003
Posts: 4,883 Likes: 12
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 4,883 Likes: 12 |
param19 for DNA?? You could compare with a Poisson-Boltzmann calculation.
Lennart Nilsson Karolinska Institutet Stockholm, Sweden
|
|
|
|
Joined: Oct 2008
Posts: 55
Forum Member
|
OP
Forum Member
Joined: Oct 2008
Posts: 55 |
I'm using param22 force field for the calculation. The command doesn't matter because the variable GBPARAMS is the same for both cases.
--------------------------- CHARMM c32b1 driven by RHEL 2.6.9-22.0.2 on PPC64
|
|
|
|
Joined: Sep 2003
Posts: 8,658 Likes: 26
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 8,658 Likes: 26 |
Yes, PARAM19 is for proteins only; there is an analogous extended (united) atom set for nucleic acids (toprna10r_22.inp, pardna10_22.inp) but I'm not sure if solvation parameters for it have been included in any of GB based implicit solvent models.
Note that param22 is also for proteins only; the nucleic acid set is param27.
Rick Venable computational chemist
|
|
|
|
Joined: Oct 2008
Posts: 55
Forum Member
|
OP
Forum Member
Joined: Oct 2008
Posts: 55 |
My charmm is a little bit old (c32b1), so I'm not sure whether the force field I'm using is param22 or param27. But it does have residue topology definition for RNA as well as patches for DNA. When did param27 come out?
--------------------------- CHARMM c32b1 driven by RHEL 2.6.9-22.0.2 on PPC64
|
|
|
|
Joined: Sep 2003
Posts: 8,658 Likes: 26
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 8,658 Likes: 26 |
Since c22, the parameter set version numbers roughly correspond to the CHARMM release when they were first included in a public 'beta' distribution. Updated and more recent parameters are available via the MacKerell Lab; for carbohydrate, ether, and the new general small molecule force fields you would need to update your CHARMM release, however.
Rick Venable computational chemist
|
|
|
|
Joined: Oct 2008
Posts: 55
Forum Member
|
OP
Forum Member
Joined: Oct 2008
Posts: 55 |
I compared the solvation energies from gbmv with those from pbeq (grid size=0.4). The error is about 1%. Pretty close!
gbmv pbeq -4573.3 -4536 -4586.8 -4545.6 -4567.6 -4536.6 -4591.4 -4542.5
Last edited by Zhiguo; 11/18/09 12:56 AM.
--------------------------- CHARMM c32b1 driven by RHEL 2.6.9-22.0.2 on PPC64
|
|
|
|
Joined: Sep 2003
Posts: 4,883 Likes: 12
Forum Member
|
Forum Member
Joined: Sep 2003
Posts: 4,883 Likes: 12 |
Nice. What's the speed difference?
Lennart Nilsson Karolinska Institutet Stockholm, Sweden
|
|
|
|
|