#1154 04/01/04 12:24 AM
Joined: Feb 2004
Posts: 13
Forum Member
OP Offline
Forum Member
Joined: Feb 2004
Posts: 13
I recently switched from running c27b4 to runnin c30b1 in parallel. I was just trying to benchmark speed vs. procs on our linux cluster, beginning with two procs. I ran a script that runs successfully using c27b4 sequentially and got the following error when beginning an sd minimization with PME. Any thoughts would be appreciated

Jim Sullivan

***** LEVEL -5 WARNING FROM *****
***** FILL_CH_GRID igood .gt.LATM
******************************************


Molecular Engineering Laboratory University of Washington
Re: PME in Parallel c30b1 vs Seq c27b4
jimpsull #1155 04/06/04 10:10 PM
Joined: Nov 2003
Posts: 200
Forum Member
Offline
Forum Member
Joined: Nov 2003
Posts: 200
Jim,
THis message says that the estimated room needed for the pme reciprocal sum was not enough. Charmm made the estimate based on the assumption that your system has a relatively homogeneous charge density. The parallel work division is in slabs of space and the arrays are dimensioned with some slack but are sized using the assumption that each slab will have about the same number of atoms.

The only way that I know of for this error message to appear is if there are too many atoms in at least one slab, meaning there is some portion of space with very low density. This happens when incorrect dimensions are used or there is a vacuum bubble in the system.

If it is this, you should be able to find the uneven density visually and decide what to do about it.
Does the error message appear with -np 1? It should not. If it does, I would
like to look more closely at your system to see if there is an error in charmm.


Hope that helps. Sincerely,
Mike


Physical mail: Dr. Michael F. Crowley National Renewable Energy Laboratory, MS 3323 1617 Cole Blvd. Golden, CO 80401
Re: PME in Parallel c30b1 vs Seq c27b4
crowley #1156 04/21/04 04:33 PM
Joined: Feb 2004
Posts: 13
Forum Member
OP Offline
Forum Member
Joined: Feb 2004
Posts: 13
Thank you. I do in fact have a large stretch of vacuum in my system. I used this to achieve a psuedo-2D boundary condition. For now I am proceeding without long-range electrostatics. I am justifying this on the basis of the high ionic strength (~1 molar) of my solvent. My assumption is that this ionic strength provides adequate shielding for electrostatic interactions beyond ~14 Angstroms.

Jim Sullivan


Molecular Engineering Laboratory University of Washington
Re: PME in Parallel c30b1 vs Seq c27b4
crowley #1157 06/16/04 07:01 PM
Joined: Sep 2003
Posts: 8,506
rmv Online Content
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 8,506
We're doing some lipid monolayer simulations with a fair amount of vacuum space, and have encountered this problem. Is there a way in any existing CHARMM options or keywords to change the sizing of these arrays or change the slab orientation, etc.?




Rick Venable
computational chemist

Re: PME in Parallel c30b1 vs Seq c27b4
rmv #1158 02/22/06 10:35 PM
Joined: Sep 2003
Posts: 8,506
rmv Online Content
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 8,506
The fix for this bug, which is still in c32 beta versions, is the following change to nbonds/pme.src at about line 410--

Before:

##IF PARALLEL
latm=max( (nattot*(3+nxyslab(0)))/nfft3*2,1)
##ELSE
latm=nattot
##ENDIF

After:


##IF PARALLEL
C latm=max( (nattot*(3+nxyslab(0)))/nfft3*2,1)
C OMIT REDUCTION FOR PARALLEL; VACUUM SPACE FIX
latm=nattot
##ELSE
latm=nattot
##ENDIF

The reduction for parallel was added for a specific machine type, which most people don't use; it isn't needed for most modern clusters.


Rick Venable
computational chemist

Re: PME in Parallel c30b1 vs Seq c27b4
rmv #23406 02/11/10 07:58 PM
Joined: Apr 2009
Posts: 141
M
Forum Member
Offline
Forum Member
M
Joined: Apr 2009
Posts: 141
I have encountered the same problem. I used NPT in equilibration run, then used NVT in production run, in which I used the average of the plateau volume achieved by equilibration and also setting pgamma and internal piston pressure as 0 in all directions as recommended in Pressure.doc.

May I ask if there is anything wrong?

Thank you!

Re: PME in Parallel c30b1 vs Seq c27b4
mooctopus #23409 02/11/10 08:20 PM
Joined: Sep 2003
Posts: 8,506
rmv Online Content
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 8,506
What problem have you encountered? The level -5 error from the FILL_CH_GRID routine? A quick source code fix for that is shown above. Why do you ask if anything is wrong? What is your question or problem?


Rick Venable
computational chemist

Re: PME in Parallel c30b1 vs Seq c27b4
rmv #23415 02/11/10 09:34 PM
Joined: Apr 2009
Posts: 141
M
Forum Member
Offline
Forum Member
M
Joined: Apr 2009
Posts: 141
My problem is after MD simulation, the waterbox was completely distorted and the volume increased enormously, and also I found the pmxx, pmyy, pmzz, pmxy,pmyz,pmxz were not 0 during dynamics. So my settings for pmass terms actually did not work.

Last edited by mooctopus; 02/11/10 09:34 PM.
Re: PME in Parallel c30b1 vs Seq c27b4
mooctopus #23416 02/11/10 11:04 PM
Joined: Sep 2003
Posts: 8,506
rmv Online Content
Forum Member
Online Content
Forum Member
Joined: Sep 2003
Posts: 8,506
That has nothing to do with this bug report post. Post something more relevant and detailed (input script, significant output messages) in the appropriate forum. I do NVT using CPT with PCONS PINT PMASS 0. all of the time; there is no bug. You can also simply use CPT with HOOVER (w/o PCONS PINT PMASS 0.) to do NVT, but you do not get reporting of P data that way.


Rick Venable
computational chemist

Re: PME in Parallel c30b1 vs Seq c27b4
rmv #23417 02/12/10 05:56 PM
Joined: Apr 2009
Posts: 141
M
Forum Member
Offline
Forum Member
M
Joined: Apr 2009
Posts: 141
This is my script. Can I use both Hoover and Pcons Pint pmass 0?
I thought the Hoover is for temperature control.
btw, is that the same by using "cpt" and "cpt leap"?

=====scritp===
Dynamics rest cpt timestep 0.001 nstep 1000000 -
nprint 100 iprfrq 500 -
PCONst pmass 0.0 pgamma 0.0 PREFerence 1.0 -
HOOVer tmass 1000 reft 323 -
EWALD PMEWALD KAPPA 0.32 FFTX 90 FFTY 90 FFTZ 90 ORDER 6 -
CUTNB 14.0 CTONNB 10.0 CTOFNB 12.0 VDW VSWITCH NTRFRQ 10 -
inbfrq -1 ihbfrq 0 imgfrq -1 -

Last edited by mooctopus; 02/12/10 05:59 PM.