Temperature and pressure control by Guillaume Lamoureux (Guillaume.Lamoureux@umontreal.ca) and Wei Jiang (wjiang@mcs.anl.gov) and Benoit Roux (Roux@uchicago.edu) The TPCONTROL command specifies the thermodynamic ensemble to be simulated with "DYNA VV2", using extended dynamics: Nose-Hoover equations for constant volume and constant temperature (the NVT ensemble) and Anderson-Hoover equations for constant pressure and temperature (the NPT ensemble). It allows multiple thermostats. "DYNA VV2" is a velocity-Verlet algorithm created to simulate efficiently the motion of Drude oscillators (created by the DRUDE command), and it understand the special nature of the Drude oscillators. The algorithm works for non-polarizable force fields as well. It is totally distinct from "DYNA VVER". See J. Chem. Phys. 119, 3025-3039 (2003) for more details. * Syntax / Syntax of the TPCONTROL command * Description / Description of the TPCONTROL command * Dynamics / Molecular dynamics with TPCONTROL * Examples / Usage examples of the TPCONTROL command
Top Syntax of the TPCONTROL command TPCOntrol [NTHErmostats integer] [CMDAmping real] [NSTEps integer] - [IUPTen iunit] - nther{ thermostat-spec } - [ barostat-spec ] TPCOntrol OFF thermostat-spec::= THERmostat integer [TREF real] <TAU real|QREF real> - [TOLScf real] [MAXScf integer] - atom-selection atom-selection::= (see select .) barostat-spec::= BAROstat [PREF real] <BTAU real|WREF real> <FULL|ZONLY>
Top Description of the TPCONTROL command ------------------------------------------------------------------- Keyword Default Purpose ------------------------------------------------------------------- NTHErm 1 The number of separate thermostats (or heat baths). For each one, a "thermostat-spec" sequence should be given. CMDAmping ZERO The friction constant (in 1/ps) to damp the motion of the center of mass of the system. Any nonzero value will create a separate thermostat (which will actually be a "heat sink" instead of a "heat bath") coupled to the three degrees of freedom associated with the motion of the center of mass of the whole system. NSTEPs 1 (20) The number of sub-steps each timestep is divided to integrate the thermostat variables. The default value is 1 for non-polarizable systems (that is, the multi-timestep approach is usually not needed), and 20 for polarizable systems (that is, whenever Drude oscillators are present). IUPTen iunit Trigger writing the pressure tensor on every integration step to a formatted file; required for viscosity calc. *MUST* precede THER or BARO options. The file must be OPENed prior to the DYNA command. TREF 298.15 The temperature of each thermostat (in Kelvins). TAU/QREF Either TAU or QREF can be specified. TAU is the characteristic response time for each thermostat (in ps), and QREF is the inertia factor of the thermostat (in kcal*AKMA**2). If the TAU keyword is used, QREF is computed from QREF = Nf*kT*TAU**2 (where Nf is the number of degrees of freedom coupled to the thermostat and kT is the temperature of the thermostat). LANG/NHGAM/NHGAMD Keyword LANG denotes Langevin theremostat is in use. Nose-Hoover keyword TAU can NOT appear with LANG in a TPCONTROL command line. NHGAM is friction strength on center of mass of a Drude pair and NHGAMD applies to relative motion of a Drude pair. CMDAMPING or NSTEPS keyword is NOT necessary either. TOLSCF 1e-5 The tolerance on the root-mean-square force on the Drude oscillators (in kcal/Angstrom), used for the iterative solution of the induced dipoles (if TREF is zero for the thermostats coupled to Drude particles). MAXSCF 50 The maximum number of iterations for the iterative solution of the induced dipoles (if TREF is zero for the thermostats coupled to Drude particles). PREF 1.0 The pressure of the barostat (in Atmospheres). BTAU/WREF The characteristic response time for the barostat (in ps). WREF (in kcal*AKMA**2) can be specified directly, or computed from WREF = (sum_i Nf_i*kT_i)*BTAU**2, where index i identifies the thermostat, and runs from 1 to NTHER. BTAU is size- and temperature-independent. FULL/ZONLY To allow FULL relaxation of ALL the Crystal's degrees of freedom or to allow scaling along the Z-direction only (ZONLY) OFF Turns the temperature and pressure control off. ------------------------------------------------------------------- 1) NTHER For a non-polarizable system, separate thermostats could be used for the fast-moving solvent (water molecules) and for the slower-moving solute (protein). For a polarizable system generated with the DRUDE command, an additional thermostat, set at a very low temperature, should be used for the Drude oscillators. The "DYNA VV2" command will recognize the special nature of the Drude particles and apply the thermostat to the atom-Drude vibrations instead of the Drude translations. ------------------------------------------------------------------- 2) CMDAMPING To avoid any acceleration of the center of mass in "DYNA VV2", this procedure is preferable to the NTRFRQ keyword in DYNA. Use a nonzero CMDAMPING only if necessary: provided the force calculation is accurate enough, the "DYNA VV2" should not induce any significant translation of the center of mass. CMDAMPING does not apply to the rotation around the center of mass that may develop for a vacuum simulation or for a system with with spherically symmetric boundary conditions (such as defined in SSBP). ------------------------------------------------------------------- 3) NSTEPS The multi-timestep approach this parameter refers to is different from the conventional MTS-RESPA approach. It does not separate the fast and slow components of the forces on the particles, but instead uses a higher-oder integration scheme for the thermostat variables. This approach is useful when fast degrees of freedom (such as Drude oscillators) are coupled to a low-temperature heat bath. For properly chosen values for the mass of the Drude oscillators and the force constant of atom-Drude bonds, it allows to use 1 or 2 fs timesteps. The smaller the QREF is, the more such a multi-timestep approach is needed. The computational overhead of this multi-timestep integration scheme is small (and scales as O(N)), because the atomic forces do not need to be recomputed. However, it is not negligible if the system is relatively small, and one may want to use NSTEPS as small as possible (as long as it has no systematic effect on the properties of the simulation). ------------------------------------------------------------------- 4) TREF TREF is set to the "real" temperature of the system for all thermostats coupled to "real" atoms, and should be set to a very low temperature (typically, 1.0 K) for a thermostat coupled to Drude particles. Such a low temperature will maintain the oscillators close to the self-consistent field regime, and will improve the stability of the simulation. If TREF is zero (actually, if it's less than 1e-8 K) for a thermostat coupled to Drude oscillators, the "DYNA VV2" command will solve the positions of the Drude oscillators at every time step using an iterative procedure. This procedure is very inefficient and should be used for testing purposes only. The TEMPerature output for the "DYNA VV2" command corresponds to the kinetic temperature of the first selection (coupled to the first thermostat). For a complete output of the temperature, use the IUNO unit specified in DYNA. ------------------------------------------------------------------- 5) TAU/QREF The inertia factor QREF of each thermostat should be tuned so that the thermostat is following the natural temperature fluctuations of Nf degrees of freedom at temperature T. If QREF is too small, the temperature of the system will be controlled on too short a time scale, and the temperature fluctuations will be abnormal (that is, not typical of the canonical ensemble). If QREF is too large, the temperature control is inefficient, and some modes of motion of the system may not be properly thermalized. The kinetic temperatures each thermostat is controlling are printed in the IUNO unit specified in "DYNA VV2", and their distribution should be checked to see if the QREF's are too small. If a thermostat is coupled to Drude oscillators, the QREF value can be as low as the order of the multi-timestep integration scheme (NSTEPS) allows it. For the oscillators, as long as the temperature is low enough compared to the actual temperature of the system, the temperature fluctuations are meaningless. TAU is roughly size and temperature-independent, and is safer to use than QREF, which should be scaled with the size of the system and the temperature of the heat bath. ------------------------------------------------------------------- 6) LANG/NHGAM/NHGAMD Langevin thermostat can be used to replace Nose-Hoover thermostat. Especially for thermodynamic simulation with Drude oscillators Dual Langevin thermostating is strongly recommended (see the following examples). It achieves more samplings and stability. ------------------------------------------------------------------- 7) TOLSCF, MAXSCF If the iterative procedure cannot meet the tolerance criterion on the gradient in less than MAXSCF iterations, it will print a short warning message. ------------------------------------------------------------------- 8) BTAU/WREF Similar to TAU/QREF, but for the barostat. The volume fluctuations should be looked at to make sure BTAU is not too small. It BTAU is too large, the volume will equilibrate too slowly and the volume fluctuations will be underestimated (which may have thermodynamic consequences if the volume of the system is relatively small).
Top Molecular dynamics with TPCONTROL The only molecular dynamics command using the information set by TPCONTROL is "DYNA VV2". TPCONTROL shares some data structures with the NOSE command, but should not be used with "DYNA NOSE". The only two keywords "DYNA VV2" recognizes from "DYNA NOSE" are IUNO and NSNOS. (What VV2 writes in unit IUNO every NSNOS steps is not the same, however.) Similarly, the "DYNA VV2" command ignores the constant-pressure options of "DYNA CPT". For "DYNA VV2", all the information concerning temperature and pressure control should come from TPCONTROL. With TPCONTROL on, the restart file written by "DYNA VV2" contains additional information about the constraint forces applied by "SHAKE". Such a restart file can be read back only by "DYNA VV2 RESTART" (and with TPCONTROL on). With TPCONTROL off, "DYNA VV2" is performing a constant energy, constant volume simulation (and it ignores the special nature of the Drude oscillators, if any).
Top Usage examples of the TPCONTROL command All the following examples should be called immediately before calling the "DYNA VV2" command: OPEN WRITE CARD UNIT 62 NAME @name DYNA VV2 ... - IUNO 62 NSNOS 100 For a NVT simulation of a non-polarizable system: TPCONTROL NTHER 1 - THER 1 TREF 298.15 TAU 0.1 SELECT ALL END For a NPT simulation of a non-polarizable system: TPCONTROL NTHER 1 - THER 1 TREF 298.15 TAU 0.1 SELECT ALL END - BARO PREF 1.00 BTAU 0.2 To use separate thermostats for solvent and solute: TPCONTROL NTHER 2 - THER 1 TREF 298.15 TAU 0.1 SELECT SEGID WATE END - THER 2 TREF 298.15 TAU 0.2 SELECT SEGID SOLU END - BARO PREF 1.00 BTAU 0.2 For a NPT simulation with dual Nose_Hoover for Drude oscillator systems: TPCONTROL NTHER 2 NSTEP 50 - THER 1 TREF 298.15 TAU 0.1 SELECT .NOT. TYPE D* END - THER 2 TREF 1.00 TAU 0.005 SELECT TYPE D* END - BARO PREF 1.00 BTAU 0.2 For a NPT simulation with dual Langevin for Drude oscillator systems: TPCONTROL NTHER 2 NHGAM 5.0 NHGAMD 10.0 - THER 1 TREF 298.15 LANG SELECT .NOT. TYPE D* END - THER 2 TREF 1.00 LANG SELECT TYPE D* END - BARO PREF 1.00 BTAU 0.2 For a NPT simulation with dual Nose-Hoover for Drude oscillators, using an iterative procedure to solve the induced dipoles (TREF=0): TPCONTROL NTHER 2 NSTEP 50 - THER 1 TREF 298.15 TAU 0.1 SELECT .NOT. TYPE D* END - THER 2 TREF 0.00 TAU 0.005 SELECT TYPE D* END - BARO PREF 1.00 BTAU 0.2 For a NPT Crystal simulation with dual Nose Hoover for Drude oscillators: TPCONTROL NTHER 2 CMDAMP 10.0 NSTEP 20 - THER 1 TREF 298.15 TAU 0.1 SELECT .NOT. TYPE D* END - THER 2 TREF 1.00 TAU 0.005 SELECT TYPE D* END - BARO PREF 1.00 BTAU 0.2 DSCY FULL